frequency control products type dfa 14 siii revision 01 checked ne date 06.09.2005 page 12 dil 14 stratum iii tcxo dfa 14-ch (5 v) & df a 14-clh (3.3 v) key features 5 to 52 mhz stratum iii compliant over -40 to 85c up to 38.88 mhz sonet minimum clock compliant over -40 to 85c up to 52 mhz applications stratum iii & smc 12.70.1 20.30.1 h0.1 7.62 15.24 pin 1 0.45 6.3 0.750.1 h = 8.50 mm function dfa 14 n/c 1 gnd 7 output 8 vcc 14 type dfa 14-ch dfa 14-clh frequency range 5 to 20 mhz, soon to 38.88 mhz* (bsm & esm up to 52 mhz*) standard frequencies 12.8, 16. 384, 19.44, 20, 34.368*, 38.88* & 44.736* mhz electrical specifications supply voltage 5 v 5 % 3.3 v 5 % supply current ( no load) 20 ma 10 ma output load hcmos 15 pf or 2 ttl hcmos 15 pf or 2 ttl duty cycle @ 50% level 45/55...55/45 % 45/55...55/45 % rise/fall times (10 to 90 %) 5 ns 5 ns high/low levels or output amplitude 4.5 v/ 0.5 v 2.8 v/ 0.3 v start-up 10 ms @ 4.75 v 10 ms @ 3.15 v frequency stability detailed tolerances [ ppm ] temperature model stability versus : overall holdover 24 hrs calibration type range code temperature vcc 5 % age ing stability stability drift @ 25c telcordia gr-1244 core stratu m iii or itu-t g.813 option 1 0 to 50c as3 0 to 70c bs3 -20 to 70c* cs3 all types -40 to 85c* es3 0.28 0.3 3 over 15 years 4.6 over 15 years 0.37 0.04 0.8 telcordia gr-253 core smc or itu-t g.813 option 2 0 to 70c bsm all types -40 to 85c esm 3.5 0.3 10 over 20 years 20 over 20 years 4.6 0.5 1 definitions 24 hours drift gr-1244-core, gr-253-core or g.813 24 hours holdover mode over full temperature range and vcc 0.5 % ordering code type + option code + frequency + model code example dfa 14-clh 19.44 mhz esm * preliminary, please consult factory for details
|